Reinforced with 0.1 mm thick perforated reed plate (material: AISI 316). For medium and higher pressures.

Variants

No results...

Product description

Reinforced with 0.1 mm thick knotted perforated sheet (material: AISI 316) to increase resistance to specific flange pressures and resistance to blow-out. Suitable for medium and higher pressures.

Available plate thicknesses: 0.5 - 1.0 - 1.5 - 2.0 - 3.0 mm

Slab dimensions: 1000 x 1000 mm; 1500 x 1500 mm on request

Features

Feature Value Unit
Operating temperature Teplotní odolnost grafitu je ovlivněna jeho čistotou - čím vyšší čistota, tím nižší oxidace (úbytek materiálu) za vyšších teplot.
-200 to 450 °C
Operating pressure
0 to 40 bar
Non-standard pressure Vysekávaná těsnění jsou standardně dimenzovaná pro použití do 40 barů (v závislosti na typu spoje). Pro vyšší tlaky doporučujeme kovová těsnění nebo aplikaci konzultujte.
41 to 120 bar
Compressibility V závislosti na tloušťce materiálu.
28 - 42 %
Reverse suspension
13 - 19 %
Specific gravity of the foil 0 ± 5 %
1 g/cm³
Graphite content
> 99 %
Sulfur content
< 750 ppm %
Content of leachable chlorides
< 40 ppm -

Questions and Answers

The highest temperature and pressure levels quoted do not in themselves determine the suitability of the material for a particular application. These limits are influenced by a number of factors such as flange type, bolts, seal installation and variable loads. Consequently, the maximum values and pT diagrams quoted offer only general recommendations.

For graphite seals, one of the main parameters is oxidation, which is the loss of material due to temperature and oxygen. This can cause a reduction in bolt tension, a reduction in seal pressure and ultimately lead to leaks in flange connections. The quality of graphite is determined by its purity, as higher levels of chlorides, fluorides and sulphur can increase oxidation and cause pitting corrosion. TGA analysis is used to detect oxidation by measuring weight loss. The higher the loss in TGA analysis, the lower the quality of the graphite.

In general, temperature and light exposure do not significantly affect the life of graphite materials. However, to ensure a shelf life of more than 10 years, observe the following storage conditions:

  • Temperature range between -20 °C and +50 °C.
  • Keep the storage area clean and dry (avoid flying dust and aggressive gases or fumes)
  • Place the material horizontally on a shelf or rack
  • Because graphite materials are inherently compressible, they are also susceptible to surface scratches. To prevent or limit possible damage to the surface of the material, take care to avoid contact with any surface containing loose dirt or other elements that could cause damage.

Graphite has excellent chemical resistance. It is highly resistant to most acids, bases, solvents and corrosive chemicals, except strong oxidizing agents. Its inert nature and compatibility with a wide range of chemicals ensures reliable sealing performance in harsh environments.

Don't see the right gasket in our offer?

We can create the perfect seal for your needs, including non-standard sizes.

Contact us

You might find it useful

Bespoke production of gaskets

Bespoke production of gaskets

Custom made gaskets Production on hydraulic and mechanical presses and CNC machines. We are able to produce seals of complex geometric shapes and large dimensions, with self-adhesive coating, in whole

More information
POWERgraf

POWERgraf

Material range of graphite products

More information

Are you ready to put your seal selection worries behind you? Contact us

and get valuable advice and information on industrial seals

Logo Pokorny Industries

Pokorny Industries Partnership in quality

© Pokorny industries s.r.o. 2024 - all rights reserved

Submit a notification

Personal data protection

Terms and Conditions

Made by servisdesign